![]() ![]() Was the post useful? Click on the white KUDOS! Star. Smart Array P812/P410/P410i Controllers Configured with SAS Expanders - Logical Drives May Disappear and "No Drive Detected" Error Message May Be Displayed After Power-Cycling the Server. Smart Array P212/P410/P410i/P411 Controllers - POST Errors, Device ID Errors, and Controller Initialization Failures That May Be Due to Improper Handling of Cache Modules or Other Possible Causes. Power up the server, if the failure still occurs, isolate the cable(s) and backplane(s). Remove all disks from the backplane by unplugging, but not fully removing from the disk slots.Ĥ. Isolate one item at a time until the faulty assembly is identified.ģ. If the error does not occur, then the fault is either cable(s), backplane(s) or disk(s). Disconnect the sas/sata data cable from the controller and post the server. ![]() A logical disk was made on the RAID array 1 + 0 of 4 disks 146 GB. 1783-Slot 0 Drive Array Controller Failure Self-test failure (cmd 0h, err 00h, loockup 0DEAD: DEADh) The server does not load. HPE Blog, Austria, Germany & Switzerlandĭid you try another BBWC with this P410i?ġ. When loading the server on the screen, I get the RADI-controller error: Slot 0 HP Smart Array P420i Controller Initializing. Hey there I've got the dreaded but not uncommon: Slot 0 HP Smart Array P420i Controller nitializing 1783-Slot 0 Drive Array Controller Failure Self-test failure (cmd0h, err00h, lockup0DEAD:DEADh) I have reseated the cache card already, checked the SAS cables.